    균열 및 비균열 콘크리트에서의 힐티 HVU2 접착 캡슐 시스템

     

    Specifications / Assumptions: 


    ASTM A193 Grade B7 threaded rod 
    Normal weight concrete, f'c = 4,000 psi 
    Seismic Design Category (SDC) B 

    No supplementary reinforcing in accordance with ACI 318 will be provided. 

    Assume maximum short term (diurnal) base material temperature < 130° F. 

    Assume maximum long term base material temperature < 110° F. 

    Assume installation in dry concrete and hammer-drilled holes. 

    Assume concrete will remain uncracked for service life of anchorage. 

     


    Dimensional Parameters: 

    hef = 4.25 in. 
    s = 4.0 in. 
    Camin = 2.5in. 
    Ah = 12.0 in. 
    d = 1/2 in.